Valcourt – FP11 - Frontenac wood fireplace
Valcourt FP11 — Decorative Wood Fireplace
The Valcourt FP11 Frontenac is a grand, clean-burning wood fireplace that heats up to 1,000 sq ft efficiently while exceeding EPA Phase II standards with emissions under 5.1 g/kg for cleaner air.
- Huge guillotine ceramic-glass door that disappears into the hearth for unobstructed flame views
- EPA Phase II qualified—approximately 70% lower particulate emissions than unqualified models
- Stunning 9.4 cu ft firebox with 30″ log capacity and robust molded refractory panels
- Includes fresh-air intake adapter for added draft stability
Quick Facts
- BTU: —
- Heats up to: 1,000 sq ft
- Burn time: —
- Emissions: below 5.1 g/kg — EPA Phase II qualified
- Type: Non-catalytic
- Manual: Download (PDF)
Technical Specifications
Brand | Valcourt |
---|---|
Model | FP11 Frontenac |
Performance
BTU | — |
---|---|
Heating Capacity | 1,000 sq ft |
Burn Time | — |
Emissions | below 5.1 g/kg — EPA Phase II qualified |
Combustion Type | Non-catalytic |
Clearances & Installation
Rear / Side / Corner / Hearth | — / — / — / — |
---|---|
Flue Diameter | 8" |
Venting | Standard 8″ chimney (Class A) |
Outside Air Kit | Yes (fresh-air intake adapter included) |
Materials & IDs
Firebox | Molded refractory panels with cast iron andirons |
---|---|
Glass | Ceramic glass |
Dimensions (W×H×D) | 60" × 74 3/4" × 36 1/4" |
Firebox Volume | 9.4 cu ft |
Weight | 920 lb |
Blower Compatible | — |
Ash Pan | — |
SKU / MPN / GTIN | — / — / 773388253114 |
Documents (PDF): Owner’s Manual
FAQs
What room size will this heat?
Plan ~20–25 BTU per sq ft. This model is rated up to 1,000 sq ft. Always size to insulation and your regional climate.
Is it EPA-certified?
Yes—EPA Phase II qualified with emissions below 5.1 g/kg. See the manual (PDF) for test data.
Catalytic vs. non-catalytic—what’s the difference here?
This is a non-catalytic unit. Non-catalytic fireplaces are simpler to operate and offer lively flames, though catalytic models typically deliver longer burns and lower emissions.
Do I need an Outside Air Kit?
Yes—a fresh-air intake adapter is included. For tighter homes, an outside air kit ensures stable draft and optimal performance.
What clearances should I plan?
See the Specs tab for the clearance table. Always adhere to the installation guidelines in the manual (PDF).
Which venting and hearth pad do I need?
Requires a standard 8″ Class A chimney. See internal venting and hearth pad options on PureFlameCo for compatible accessories.
Can I add a blower?
Not specified. Blowers may enhance heat distribution in larger rooms—see our PureFlameCo accessories for options.
What’s the warranty and return policy?
Covered by Valcourt’s limited lifetime manufacturer warranty for residential use. Returns follow PureFlameCo’s standard policy.
How does shipping work?
Ships freight curbside. Inspect the package upon arrival and note any damage on delivery documentation before signing.
Warranty
Valcourt FP11 Frontenac — Manufacturer warranty summary: Limited lifetime warranty on key components for residential use.
Coverage
Component | Term | Notes |
---|---|---|
Firebox/Body | Lifetime | Original purchaser; residential use only |
Internal Parts | Lifetime (select), 5 years (others) | Varies by part; refer to warranty PDF |
Catalyst | n/a | Model is non-catalytic |
Glass | Lifetime | Ceramic glass; limited to one replacement |
Electrical/Blower | 2 years | Controls, wiring, blower parts |
Paint/Finish | 1 year | Includes gaskets and refractory bricks |
Exclusions & Conditions
- Void if misused, over-fired, improperly installed, altered, or used with non-cordwood fuel.
- Only covers original purchaser; proof of purchase, model name, and serial number required.
- Installation must follow manual and local codes; improper installation voids warranty.
- Damage from transportation, misuse, lack of maintenance, unauthorized parts, or cosmetic issues (scratches, discoloration) is excluded.
How to Make a Warranty Claim
- Retain proof of purchase and serial/model information.
- Contact PureFlameCo Support with photos and issue description.
- Obtain manufacturer authorization before repair or part replacement.
Official Documents (PDF): Manufacturer Warranty
If official warranty terms could not be verified, please contact support for confirmation.
Manuals & Installation
Always follow the official Valcourt documentation for safe installation and operation of the FP11 Frontenac. Professional installation by certified technicians (NFI, WETT, or APC) is strongly recommended, and local permits are required in most areas.
Downloads
Installation Highlights
- Complies with NFPA 211 (USA) and CSA B365 (Canada); follow all local codes.
- Non-combustible surround materials (cement board, etc.) are required.
- Includes a fresh-air intake adapter; duct per manual instructions.
- Requires an 8″ Class A chimney; follow venting specifications in the manual.
- Reference guide provides quick framing dimensions and clearance tables.